Clean Room Monitor, 2-Row Display, Ethernet & Datalogging in CSV files
Share this product with friends

Whatsapp

Telegram

Facebook

Twitter

Email

Messanger

Clean Room Monitor, 2-Row Display, Ethernet & Datalogging in CSV files

Model : Hawkeye-2 Row, Ethernet

  1. No of Input - 2
  2. Potential free Digital Input for AHU status
  3. Real Time Clock with battery Backup
  4. 3 programmable Alarms with visual annunciation
  5. No-touch operation for Alarm Acknowledge
  6. 2 x 4-20mA or 0-10V analog output
  7. 18-35 VDC supply
  8. 2 row, 0.8” seven segment Display
  9. Ethernet / Modbus TCP
  10. Datalogging for 21 days, 1 CSV file per day
Read More...

Hawkeye 2-Row Display, Clean Room Monitor With Ethernet & Datalogging

2 x Integral, Remote, Slave Inputs

20-30 VDC

3+3 (0.8'') Display Digits

Modbus TCP & telnet

21 days datalogging

Similar Products

product Clean Room Monitor, 3 Row
Clean Room Monitor, 3 Row |Hawkeye-3 Row

  1. 3 channel RH, Temperature & DP measurement
  2. Potential free digital input for AHU status
  3. 3 programmable alarms with visual annunciation
  4. No-touch operation for alarm acknowledge
  5. 3 x 4-20 mA or 0-10 V analog output
  6. RS485 Modbus® RTU
  7. 18-35 VDC supply
  8. 3-digit, 0.8” seven segment display
  9. Datalogging feature
  10. Process value, alarm and time stamp logging
  11. Memory for 31 days with 1 minute datalogging interval
  12. Full datalogging control through utility
Read More...

product Clean Room Monitor, With RTC
Clean Room Monitor, With RTC |Hawkeye-RTC

  1. 3 Channel RH, Temperature & DP measurement
  2. Potential free digital input for AHU status
  3. Real time clock with battery backup
  4. 3 programmable alarms with visual annunciation
  5. No-touch operation for Alarm Acknowledge
  6. 3 x 4-20mA or 0-10V analog output
  7. RS485/Modbus RTU
  8. 18-35 VDC supply
  9. 4 row, 0.56” seven segment Display
  10. Datalogging feature
  11. Process value, alarm and time stamp logging
  12. Memory for 31 days with 1 minute datalogging interval
  13. Full datalogging control through utility
Read More...

product Clean Room Monitor, 3-Row Display, Ethernet & Datalogging in CSV files
Clean Room Monitor, 3-Row Display, Ethernet & Datalogging in CSV files |Hawkeye-3 Row, Ethernet

  1. 3 Channel RH, Temperature & DP measurement
  2. Potential free Digital Input for AHU status
  3. 3 programmable Alarms with visual annunciation
  4. No-touch operation for Alarm Acknowledge
  5. 3 x 4-20mA or 0-10V analog output
  6. 18-35 VDC supply
  7. 3-digit, 0.8” seven segment Display
  8. Ethernet / Modbus TCP
  9. Datalogging for 21 days, 1 CSV file per day
Read More...

product RTC Clean Room Monitor, Ethernet & Datalogging in CSV files
RTC Clean Room Monitor, Ethernet & Datalogging in CSV files |Hawkeye-RTC, Ethernet

  1. 3 Channel RH, Temperature & DP measurement
  2. Potential free Digital Input for AHU status
  3. Real Time Clock with battery Backup
  4. 3 programmable Alarms with visual annunciation
  5. No-touch operation for Alarm Acknowledge
  6. 3 x 4-20mA or 0-10V analog output
  7. 18-35 VDC supply
  8. 4 row, 0.56” seven segment Display
  9. Ethernet / Modbus TCP
  10. Datalogging for 21 days, 1 CSV file per day
Read More...

Customers Also Viewed

product Single/Dual Channel PID Controller, Full-featured, 96Wx48Hx60D
Single/Dual Channel PID Controller, Full-featured, 96Wx48Hx60D |NEX202

  1. Single / Dual loop PID / Heat+Cool PID / 16-step profile control
  2. Universal input
  3. 4 relays, 2 isolated analog outputs, RS485 Modbus® RTU
  4. 3 digital inputs
  5. Field-selectable control device (relay/SSR/analog output)
Read More...

product Dual Relative Humidity / Temperature 2-Wire Output Transmitter, Wall & Duct
Dual Relative Humidity / Temperature 2-Wire Output Transmitter, Wall & Duct |RHT861

  1. 4 analog isolated outputs with true 2-wire operation, 2 RH, 2 T, 4 RH, 4 T
  2. Isolation : 1500 VAC RMS, 50 Hz/1 minute
  3. Precision Class A Pt100, Pt500, Pt1000 or band gap temperature sensor options
  4. Accuracy ±2% RH, ±0.5 deg C for band gap & ±0.2 deg C for RTD Class A sensor
  5. Any number of outputs (1-4) can be assigned to any parameter : RH, T or dew point
  6. Dual row 7 segment LCD option to display Relative Humidity, Temperature or Dew point (programmable)
  7. Parameter configuration via LCD & keys or remote display module or PC configurator using USB to Serial Converter DCC501
Read More...

product Flameproof GPS Clocks - RF, RS485 Master Clock
Flameproof GPS Clocks - RF, RS485 Master Clock |GMC201 FLP-RF

  1. Time Source - GPS satellite or NTP server
  2. Ethernet communication for reduced synchronizing time
  3. Software for synchronizing PC time
  4. Wireless solution for reduced cabling
  5. Range expansion without using additional hardware
  6. Built-in RTC with battery backup
  7. 39 Timezones and Daylight Saving Time adjustment
  8. 12H and 24H format
  9. User friendly interface for configuration
  10. IP65 and Flameproof compliance
  11. 2.3” and 4.0” super bright seven segment LED display
  12. Multiple colour options - Red, green and white colours
  13. Multiple mounting arrangements like Table-top, wall mount, flush mount and hanging models
  14. Health monitoring utility for Ethernet and RS485 clocks
  15. Parameter configuration utility for master clocks and RS485 clocks
  16. Provision to update RTC of RS485 devices


Read More...

product Analog Input Module
Analog Input Module |SCM201

  1. 8 universal analog inputs
  2. Isolated RS485/MODBUS RTU, Upto 57600 Baud
  3. 85-265 VAC or 15-60 VDC supply
  4. 3 key, 3 level programming
  5. Powerful, flexible SCADA software available
  6. 4-20 mA output option (Tmax version with 4~20 mA for highest PV (from all channels)
  7. Standard & High Performance Version